SITI, AMINAH (2024) ANALISIS DESAIN VENTILASI UDARA TERHADAP KELAYAKAN KENYAMANAN PADA RUANG PRODUKSI PT.AAA. Other thesis, UNIVERSITAS GRESIK.
Text (01 COVER)
01. COVER.pdf Download (5MB) |
|
Text (02 BAB 1)
02. BAB 1.pdf Download (216kB) |
|
Text (03 BAB 2)
03. BAB 2.pdf Restricted to Repository staff only Download (803kB) |
|
Text (04 BAB 3)
04. BAB 3.pdf Restricted to Repository staff only Download (630kB) |
|
Text (05 BAB 4)
05. BAB 4.pdf Restricted to Repository staff only Download (980kB) |
|
Text (06 BAB 5)
06. BAB 5.pdf Restricted to Repository staff only Download (190kB) |
|
Text (07 DAFTAR PUSTAKA)
07. DAFTAR PUSTAKA.pdf Download (185kB) |
|
Text (08 LAMPIRAN)
08. LAMPIRAN.pdf Restricted to Registered users only Download (893kB) |
|
Text (09 CEK PLAGIASI)
09. CEK PLAGIASI.pdf Restricted to Registered users only Download (12MB) |
|
Text (10 LEMBAR PERSETUJUAN UMUM)
10. LEMBAR PERSETUJUAN.pdf Restricted to Registered users only Download (6MB) |
Abstract
Ventilation as a building's air conditioning system has an important role in controlling temperature, air humidity, air quality and air movement. The function of ventilation, apart from producing clean air, also functions to remove polluting gases (contaminants). This research is entitled "ANALYSIS OF AIR VENTILATION DESIGN ON COMFORT FEASIBILITY IN PT. Organic Compounds (VOC). The method used in this research is a quantitative method with a descriptive approach. By using GVR calculations in accordance with SNI standards regarding procedures for designing ventilation systems (SNI 03-6572 (2001)). This research was carried out using an anemometer and an air quality detector to find wind speed, temperature and air quality values. The research results from a room area of 22 m² with a total of 5 employees and 1 exhaust fan and 1 AC and without natural ventilation in the form of windows had a room temperature of 30˚C and humidity of 54% showed that the condition of the room was less comfortable. The existing ventilation in a room measuring 22 m² shows that the air ventilation in the production room does not meet existing standards, which should have a total ventilation area of 10% of the floor area, namely 2.2 m². So in this case it is necessary to add natural ventilation in the form of casement windows with a size of 0.6x1.5, 2 pieces and also replace the exhaust fan with a size of 0.7x0.7 m, 1 piece
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | Acute Respiratory Infection, Industrial hygiene, Production Room, SNI 6572-2001, Ventilation |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Depositing User: | SITI AMINA SITI AMINAH SITI AMINAH |
Date Deposited: | 16 Jul 2024 03:44 |
Last Modified: | 16 Jul 2024 03:44 |
URI: | http://elibs.unigres.ac.id/id/eprint/2537 |
Actions (login required)
View Item |